d23004
2023-05-24 fa87a558389d9d425f70afa1c8de54c69875ef2c
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading;
using System.Threading.Tasks;
 
namespace SA_LTT.Module
{
    public class GR200 : ComPort
    {
        private char STX = Convert.ToChar(2);
        private char EXT = '\n';
        private Dictionary<int, float> _measuredValues;
 
        public float MainCDAPressure
        {
            get
            {
                return _measuredValues[1];
            }
        }
 
        public float MainVacuumPressure
        {
            get
            {
                return _measuredValues[2];
            }
        }
 
        public float N2PTPressure
        {
            get
            {
                return _measuredValues[3];
            }
        }
 
        public float MainCDAFlow
        {
            get
            {
                return _measuredValues[4];
            }
        }
 
        public float ChamberVacuumPressure
        {
            get
            {
                return _measuredValues[5];
            }
        }
 
        private Equipment _equipment;
        private Thread t_statusUpdate;
 
        public GR200(Equipment equipment)
        {
            serialPort.PortName = "COM7";
            serialPort.BaudRate = 57600;
            serialPort.Parity = System.IO.Ports.Parity.None;
            serialPort.DataBits = 7;
            serialPort.StopBits = System.IO.Ports.StopBits.One;
            serialPort.Handshake = System.IO.Ports.Handshake.RequestToSend;
            Terminator = "\r\n";
 
            _measuredValues = new Dictionary<int, float>();
 
            for (int i = 1; i <= 12; i++)
            {
                _measuredValues.Add(i, 0f);
            }
 
            _equipment = equipment;
 
            t_statusUpdate = new Thread(statusUpdate);
            t_statusUpdate.Start();
        }
 
        public void statusUpdate()
        {
            while (_equipment.IsDisposed == false)
            {
                try
                {
                    Thread.Sleep(100);
 
                    if (IsOpen)
                    {
                        ReadMeasuredValue(1);
                    }
                    else
                    {
                        if (_equipment.alarmManager.OccurredAlarms.Exists(x => x.Code == AlarmCode.AL_0058_GR200_DISCONNECTED))
                        {
 
                        }
                        else
                        {
                            if (Open() == false)
                            {
                                _equipment.alarmManager.Occur(AlarmCode.AL_0058_GR200_DISCONNECTED);
                            }
                        }
                    }
                }
                catch (Exception e)
                {
                    EquipmentLogManager.Instance.WriteExceptionLog(e.StackTrace);
                }
            }
        }
 
        private string GetCommand(int channel, int bitsCount, int registerNumber)
        {
            return $"{channel:D2}DRS,{(bitsCount):D2},{registerNumber:D4}";
        }
 
        public void ReadMeasuredValue(int channel)
        {
            string command = GetCommand(channel, 24, 16);
            string receivedData = string.Empty;
 
            if(WriteRead(command, out receivedData))
            {
                string[] datas = receivedData.Split(',');
 
                int register = 1;
 
                if (!datas[0].Contains("NG") && datas[0].Contains("DRS"))
                {
                    for (int i = 2; i < datas.Length; i = i + 2)
                    {
                        float fl = BitConverter.ToSingle(BitConverter.GetBytes(Convert.ToInt64(datas[i] + datas[i + 1], 16)), 0);
 
                        if (_measuredValues.ContainsKey(register))
                        {
                            _measuredValues[register] = fl;
                        }
                        else
                        {
                            _measuredValues.Add(register, fl);
                        }
 
                        register++;
                    }
                }
                else if (datas[0].Contains("NG"))
                    throw new Exception($"Command NG, Address : {channel}, Command : DRS , Recv Data =");
                else
                    throw new Exception($"Error, Address : {channel}, Command : DRS , Recv Data =");
            }
        }
 
        public bool WriteRead(string command, out string receivedData)
        {
            string data = base.WriteRead($"{STX}{command}\r{EXT}");
 
            if (data.StartsWith($"{STX}"))
            {
                receivedData = data.Replace(STX, ' ').Replace("\r\n", "");
                return true;
            }
            else
            {
                receivedData = string.Empty;
                return false;
            }
        }
    }
}