From 14f07cdcb29fbae3cc55e217201c9cbfdd99e4d8 Mon Sep 17 00:00:00 2001
From: 천호석 <hosuk1418@naver.com>
Date: 월, 21 11월 2022 13:34:53 +0900
Subject: [PATCH] auto mode 일 때 key switch 돌리지 못하도록 수정.

---
 SHARP_CLAS_UI/500.Equipment/Equipment.cs |   17 ++++++++++++++---
 1 files changed, 14 insertions(+), 3 deletions(-)

diff --git a/SHARP_CLAS_UI/500.Equipment/Equipment.cs b/SHARP_CLAS_UI/500.Equipment/Equipment.cs
index d7af1b8..968945a 100644
--- a/SHARP_CLAS_UI/500.Equipment/Equipment.cs
+++ b/SHARP_CLAS_UI/500.Equipment/Equipment.cs
@@ -564,7 +564,7 @@
         private User_Info _user;
         private SequenceTimer _modeChangeTime = new SequenceTimer();
 
-        private string _programVersion = "001.002.000";
+        private string _programVersion = "001.002.001";
         #endregion
 
         #region Construct
@@ -578,7 +578,7 @@
 
             power_meter = new Power_Meter(this, "COM3");
             power_meter.Open();
-
+            power_meter.HandShakingOn();
             Create_Exception_logger();
             Create_Panel_Info_logger();
             Create_Tact_Time_logger();
@@ -978,7 +978,12 @@
 
                 if (!Align_vision.isConnected) Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0510_ALIGN_VISION_DISCONNECT);
                 if (!Aoi_vision.isConnected) Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0511_AOI_VISION_DISCONNECT);
-                if (!power_meter.isOpen && !Alarm_Manager.Instance.Occured_List.Exists(X => X.Code == En_Alarm_List.AL_0930_POWER_METER_DISCONNECTED)) { Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0930_POWER_METER_DISCONNECTED); power_meter.Open(); }
+                if (!power_meter.isOpen && !Alarm_Manager.Instance.Occured_List.Exists(X => X.Code == En_Alarm_List.AL_0930_POWER_METER_DISCONNECTED))
+                {
+                    Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0930_POWER_METER_DISCONNECTED);
+                    power_meter.Open();
+                    power_meter.HandShakingOn();
+                }
 
                 if (equip_mode == En_Equipment_Mode.Auto && dt.Second % 10 == 0 && (loader.Panel_Exist && before.Panel_Exist && process.Panel_Exist && after.Panel_Exist && unloader.Panel_Exist) && !units.Exists(x => x.sequenceChangedTime.Minute < 10))
                 {
@@ -1457,6 +1462,12 @@
                         return false;
                     }
                     
+                    if(Door_Opened)
+                    {
+                        Interlock_Manager.Add_Interlock_Msg("Can't Change auto mode.", "Please door close.");
+                        return false;
+                    }
+
                     if(!Is_Home_Complete)
                     {
                         Interlock_Manager.Add_Interlock_Msg("Can't Change auto mode.", "Please Set Home.");

--
Gitblit v1.9.3