From 50b35174180ccb34dda39251393ba031ca69e69e Mon Sep 17 00:00:00 2001
From: 천호석 <hosuk1418@naver.com>
Date: 금, 02 12월 2022 17:34:09 +0900
Subject: [PATCH] auto power 측정시 laser 출사 위치에서 power meter위치가 아닐 때 laser off 후 첫 step으로 이동

---
 SHARP_CLAS_UI/500.Equipment/400.Module/300.CIM/CIM_Client.cs |   10 +++++++++-
 1 files changed, 9 insertions(+), 1 deletions(-)

diff --git a/SHARP_CLAS_UI/500.Equipment/400.Module/300.CIM/CIM_Client.cs b/SHARP_CLAS_UI/500.Equipment/400.Module/300.CIM/CIM_Client.cs
index 8609d98..15a4c31 100644
--- a/SHARP_CLAS_UI/500.Equipment/400.Module/300.CIM/CIM_Client.cs
+++ b/SHARP_CLAS_UI/500.Equipment/400.Module/300.CIM/CIM_Client.cs
@@ -597,8 +597,16 @@
             data_etc += $"{info.AblationTargetPower:f3}" + ",";
             data_etc += $"{info.Film_Judge_Result:f3}" + ",";
             data_etc += $"{info.Fine_Align_Distatnce:f3}" + ",";
+            data_etc += $"{info.Mark1Width:f3}" + ",";
+            data_etc += $"{info.Mark2Width:f3}" + ",";
+            data_etc += $"{info.Mark3Width:f3}" + ",";
+            data_etc += $"{info.Mark4Width:f3}" + ",";
+            data_etc += $"{info.Mark5Width:f3}" + ",";
+            data_etc += $"{info.Mark6Width:f3}" + ",";
+            data_etc += $"{info.Mark7Width:f3}" + ",";
+            data_etc += $"{info.Mark8Width:f3}" + ",";
 
-            for (int i = 94; i < 380; i++)
+            for (int i = 102; i < 380; i++)
             {
                 data_etc += $",";
             }

--