From 58a2c7fa01a617e6de69b85905bb645f08fac656 Mon Sep 17 00:00:00 2001 From: 천호석 <hosuk1418@naver.com> Date: 화, 06 12월 2022 13:51:35 +0900 Subject: [PATCH] Auto & Manual 상태 일 때 power meter 측정 위치 및 가공 위치에서만 Laser on 할 수 있도록 Interlock 추가 --- SHARP_CLAS_UI/500.Equipment/700.Unit/000.Loader/LoaderLiftOut.cs | 32 ++++++++++++++++++++++++++++++-- 1 files changed, 30 insertions(+), 2 deletions(-) diff --git a/SHARP_CLAS_UI/500.Equipment/700.Unit/000.Loader/LoaderLiftOut.cs b/SHARP_CLAS_UI/500.Equipment/700.Unit/000.Loader/LoaderLiftOut.cs index cc0066b..bbe5f51 100644 --- a/SHARP_CLAS_UI/500.Equipment/700.Unit/000.Loader/LoaderLiftOut.cs +++ b/SHARP_CLAS_UI/500.Equipment/700.Unit/000.Loader/LoaderLiftOut.cs @@ -303,6 +303,18 @@ { Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0130_LD_TRAT_OUT_LIFT_Z_POWER_OFF); } + else if (IsLiftInSensor1 || IsLiftInSensor2) + { + Interlock_Manager.Add_Interlock_Msg("Loader Lift empty", "Home can't run, Lift in sensor detected."); + } + else if (IsLiftLimitSensor1 || IsLiftLimitSensor2) + { + Interlock_Manager.Add_Interlock_Msg("Loader Lift empty", "Home can't run, Lift limit sensor detected."); + } + else if (Clamper.ClampSol) + { + Interlock_Manager.Add_Interlock_Msg("Loader Lift empty", "Home can't run, Clamp is clamped "); + } else { _homeStep = LiftHomeSteps.S1100_CONVEYOR_HOME_CHECK; @@ -359,7 +371,22 @@ } else { - _homeStep = LiftHomeSteps.S1300_MOVE_STAY_POSITION; + if (equipment.loader.ConveyorOut.IsLiftInSensor || equipment.loader.ConveyorOut.IsLiftInCompleteSensor) + { + if (equipment.loader.ConveyorOut.IsLiftInSensor) + { + Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0592_LD_TRAY_OUT_CONVEYOR_LIFT_IN_SENSOR_CHECK); + } + + if (equipment.loader.ConveyorOut.IsLiftInCompleteSensor) + { + Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0593_LD_TRAY_OUT_CONVEYOR_LIFT_IN_COMPLETE_SENSOR_CHECK); + } + } + else + { + _homeStep = LiftHomeSteps.S1300_MOVE_STAY_POSITION; + } } break; } @@ -1100,6 +1127,8 @@ { if (IsStayPosition) { + _trayCount = 0; + if (equipment.loader.ConveyorOut.IsLiftInSensor || equipment.loader.ConveyorOut.IsLiftInCompleteSensor) { Step = LiftOutSteps.S2420_CONVEYOR_UNLOAD; @@ -1128,7 +1157,6 @@ { if (equipment.loader.ConveyorOut.IsWorkEnd) { - _trayCount = 0; if (equipment.cim_mode == En_Cim_Mode.Online) { Step = LiftOutSteps.S2500_PORT_STATUS_CIM_SEND; -- Gitblit v1.9.3