From 58fb7ef7cdec2cc22602d743368817960b9d7063 Mon Sep 17 00:00:00 2001
From: 천호석 <hosuk1418@naver.com>
Date: 금, 02 12월 2022 17:37:51 +0900
Subject: [PATCH] 장비 auto mode가 아닐 때 power meter 위치에서 벗어나 laser on 할 시 laser off 후 interlock 발생.

---
 SHARP_CLAS_UI/500.Equipment/Equipment.cs |   15 +++++++++++++++
 1 files changed, 15 insertions(+), 0 deletions(-)

diff --git a/SHARP_CLAS_UI/500.Equipment/Equipment.cs b/SHARP_CLAS_UI/500.Equipment/Equipment.cs
index 968945a..9014391 100644
--- a/SHARP_CLAS_UI/500.Equipment/Equipment.cs
+++ b/SHARP_CLAS_UI/500.Equipment/Equipment.cs
@@ -997,6 +997,21 @@
                     panel_count_info.CleaningCount = 0;
                     Panel_Count_Info_Manager.Instance.Save_Panel_Count_Info(panel_count_info);
                 }
+
+                if(equip_mode != En_Equipment_Mode.Auto) // Auto mode媛� �븘�땺 �븣 
+                {
+                    if(units.Exists(x => x.UnitMode != equip_mode) == false) //�옣鍮� �긽�깭媛� �떎瑜멸쾶 �엳�뒗吏� �솗�씤
+                    {
+                        if(process.ablation.Get_Is_Position_X_Power_Meter() && process.ablation.Get_Is_Position_Z_Power_Meter())
+                        {
+                            if (sm.Get_Bit(Input_Memory_Address.Laser_Active))
+                            {
+                                scanner.Set_Laser_Off();
+                                Interlock_Manager.Add_Interlock_Msg("Laser can't on.", "Please move power meter position.");
+                            }
+                        }
+                    }
+                }
             }
             catch(Exception e)
             {

--