From 217577e6cb9262757f709de89d97582a1fe1e5e5 Mon Sep 17 00:00:00 2001
From: 천호석 <hosuk1418@naver.com>
Date: 금, 16 12월 2022 08:37:38 +0900
Subject: [PATCH] 1. Laser on Interlock에 Power meter 위치 추가 2. Auto power 측정중 pause시 자동 종료 추가.

---
 SHARP_CLAS_UI/500.Equipment/700.Unit/400.Unloader/UnloaderLiftOk.cs |   29 ++++++++++++++++++++++++++++-
 1 files changed, 28 insertions(+), 1 deletions(-)

diff --git a/SHARP_CLAS_UI/500.Equipment/700.Unit/400.Unloader/UnloaderLiftOk.cs b/SHARP_CLAS_UI/500.Equipment/700.Unit/400.Unloader/UnloaderLiftOk.cs
index bb8e77d..51209e8 100644
--- a/SHARP_CLAS_UI/500.Equipment/700.Unit/400.Unloader/UnloaderLiftOk.cs
+++ b/SHARP_CLAS_UI/500.Equipment/700.Unit/400.Unloader/UnloaderLiftOk.cs
@@ -378,6 +378,18 @@
                         {
                             Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0450_ULD_TRAY_OK_LIFT_Z_POWER_OFF);
                         }
+                        else if(IsLiftInSensor1 || IsLiftInSensor2)
+                        {
+                            Interlock_Manager.Add_Interlock_Msg("Unloader Lift Ok", "Home can't run, Lift in sensor detected.");
+                        }
+                        else if(IsLiftLimitSensor1 || IsLiftLimitSensor2)
+                        {
+                            Interlock_Manager.Add_Interlock_Msg("Unloader Lift Ok", "Home can't run, Lift limit sensor detected.");
+                        }
+                        else if(Clamper.ClampSol)
+                        {
+                            Interlock_Manager.Add_Interlock_Msg("Unloader Lift Ok", "Home can't run, Clamp is clamped ");
+                        }
                         else
                         {
                             _homeStep = LiftHomeSteps.S1100_CONVEYOR_HOME_CHECK;
@@ -435,7 +447,22 @@
                         }
                         else
                         {
-                            _homeStep = LiftHomeSteps.S1300_MOVE_STAY_POSITION;
+                            if (equipment.unloader.ConveyorOut.IsLiftInSensor || equipment.unloader.ConveyorOut.IsLiftInCompleteSensor)
+                            {
+                                if (equipment.unloader.ConveyorOut.IsLiftInSensor)
+                                {
+                                    Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0742_ULD_TRAY_OK_CONVEYOR_LIFT_IN_SENSOR_CHECK);
+                                }
+
+                                if (equipment.unloader.ConveyorOut.IsLiftInCompleteSensor)
+                                {
+                                    Alarm_Manager.Instance.Occurred(En_Alarm_List.AL_0743_ULD_TRAY_OK_CONVEYOR_LIFT_IN_COMPLETE_SENSOR_CHECK);
+                                }
+                            }
+                            else
+                            {
+                                _homeStep = LiftHomeSteps.S1300_MOVE_STAY_POSITION;
+                            }
                         }
                         break;
                     }

--
Gitblit v1.9.3